Net Radiometer
CNR 4
Instruction Manual
Vue de la page 0
1 2 3 4 5 6 ... 36 37

Résumé du contenu

Page 1 - Instruction Manual

Net RadiometerCNR 4Instruction Manual

Page 2

9 1.1.6 Using the CNR 4 measuring Net Radiation In the CNR 4 all components are measured separately. This implies that you should

Page 3

10 Temperature [EC] Resistance [Ω] Temperature [EC] Resistance [Ω] Temperature [EC] Resistance [Ω] -30 -29 -28 -27 -26 -25 -24 -23 -22 -2

Page 4

11 Temperature [EC] Resistance [Ω] Temperature [EC] Resistance [Ω] Temperature [EC] Resistance [Ω] -30 -29 -28 -27 -26 -25 -24 -23 -22 -2

Page 5 - 1 GENERAL INFORMATION

12 1.1.6.4 Calculation of the albedo for solar radiation The albedo is the ratio of incoming and reflected Solar radiation. It is a figure so

Page 6

13 1.1.6.6 Calculation of the Net (total) radiation The Net radiation, NR, can be calculated using all 4 sensor measurement results: NR = (E

Page 7 - CNR 4 NET RADIOMETER • SENSOR

14 Typical graphs for the pyrgeometers Figure 1.2.2 partly clouded day for the upper pyrgeometer Figure 1.2.3 clear day for the downward fac

Page 8 - • TEMPERATURE

15 It is assumed that when ambient temperature varies, the Net Far Infrared radiation remains roughly the same, independent of

Page 9 - CNF 4 VENTILATION UNIT

16 2 CNR 4 PROPERTIES The CNR 4 consists of two pyranometers, for measuring solar radiation, and of two pyrgeometers for measuring Far Infrar

Page 10

17 2.1.1 Specifications of the CNR 4 General specifications Environmental 0 - 100% RH (Relative Humidity) Definition Intended for conti

Page 11

18 2.2.1 Specifications of the pyranometer Pyranometers Specification Unit Value (All indicated values are absolute values) Spectral range nm

Page 12

1 IMPORTANT USER INFORMATION Reading this entire manual is recommended for full understanding of the use of this product. The exclamati

Page 13

19 Irradiance: W/m² 0 to 2000 Definition Measurement range Non-stability % < 1 Definition Maximum change of sensitivity per year, percent

Page 14

20 2.2.2 Spectral properties of the pyranometer The spectral properties of the pyranometer are mainly determined by the properties of the abso

Page 15

21 Figure 2.4 The directional response, or cosine response, of the pyranometer: On the horizontal axis, the zenith angle is shown (0E zenith a

Page 16

22 2.3 Properties of the pyrgeometer The pyrgeometer consists of a thermopile sensor and a silicon window integrated in the CNR

Page 17 - 405 mm 347 mm

23 Definition Instrument sensitivity within a specific spectral range Sensitivity µV/W/m² 5 to 15 Definition Calibration factor Impedance Ω 20

Page 18

24 2.3.4 Spectral properties of the pyrgeometer The spectral properties of the pyrgeometer are mainly determined by the properties of the abso

Page 19

25 2.4 Properties of the CNF 4 (optional) ventilation unit The ventilator and heaters purpose is to prevent dew deposition on the pyrgeometer

Page 20

26 2.5 Properties of the Pt-100 and thermistor The Pt-100 is a common temperature sensor. Essentially it is a resistor that is temperature dep

Page 21

27 3 CALIBRATION 3.1 Calibration of the pyranometers The primary standard for pyranometers is the World Radiometric Reference. Reference pyr

Page 22

28 4 INSTALLATION AND MAINTENANCE For measurement of the Net Radiation, it is most important that the instrument is located in

Page 23

2 DECLARATION OF CONFORMITY According to EC guideline 89/336/EEC 73/23/EEC We: Kipp & Zonen B.V. Delftechpark 36 2

Page 24

29 4.2 Replacing the Ventilator Filter The CNF 4 ventilation unit has a filter that can be checked and if required cleaned or r

Page 25

30 5 TROUBLE SHOOTING This chapter describes what to do if there appears to be a problem. The following chapters give individ

Page 26

31 The CNR 4 body and ambient air should be at the same temperature as much as possible. Let the pyrgeometer rest for at least five minutes to r

Page 27

32 6 CMB 1 OPTIONAL MOUNTING BRACKET The CMB 1 mounting bracket is ideal for mounting the CNR 4 to a pole or wall. The stainle

Page 28

33 Fig 7.2 CMB 1 mounting examples with CNR 4, albedometer and pyranometer

Page 29

34 7 DELIVERY Check the contents of the shipment for completeness (see below) and note whether any damage has occurred during

Page 30

35 8 RECALIBRATION SERVICE Pyranometers, UV-meters, pyrgeometers, Net radiometers & Sunshine duration meters Kipp & Zonen solar radi

Page 31

Our customer support remains at your disposal for any maintenance or repair, calibration, supplies and spares.Für Servicearbeiten und Kalibrierung, Ve

Page 32

3 CONTENTS IMPORTANT USER INFORMATION ...

Page 33

4 1 GENERAL INFORMATION The CNR 4 is a 4 component net radiometer that measures the energy balance between incoming short-wave a

Page 34

5 1.1 Connecting the CNR 4 1.1.1 The difference between temperature and sensor connection CNR 4 has several output signals: two voltages for

Page 35 - 7 DELIVERY

6 Figure 1.2 The sensor connections of the CNR 4. The sensor has four mV outputs, 2 for the pyranometers and 2 for the pyrgeometers Ground *

Page 36 - 8 RECALIBRATION SERVICE

7 1.1.3 The radiometer Temperature connector (T) The temperature connector of the CNR 4 carries the signals for the PT-100 and T

Page 37 - Passion for Precision

8 1.1.4 The (optional) CNF 4 connector The optional ventilator CNF 4 for the CNR 1 has separate wires for heating and ventilati